Powertrain Engines
Valve Timing
• For verifying or adjusting the valve timing a timing peg (SST) has to be installed in the
blind plug hole, which is located at the rear of the cylinder block. Then turn the
crankshaft clockwise until the crankshaft counterweight of cylinder no. 1 touches the
timing peg (refer to the workshop manual for details).
NOTE: To prevent damage to the timing peg do not use it to lock the crankshaft in position.
L1001.4_01013
1 Service hole 4 TDC position
2 Crankshaft pulley 5 Crankshaft counterweight of cylinder no.1
3 Detent bolt for crankshaft pulley 6 Timing peg (SST)
Curriculum Training 01-19