3. Measure the stem diameter of each valve in X
and Y directions at the three points (A, B, and C)
as indicated in the figure.
If not as specified, replace the valve.
Standard diameter:
IN: 5.4705.485 mm {0.21540.2159 in}
EX: 5.4655.480 mm {0.21520.2157 in}
Maximum diameter:
IN: 5.440 mm {0.2142 in}
EX: 5.435 mm {0.2140 in}
4. Measure the inner diameter of each valve guide
in X and Y directions at the three points (A, B, and
C) as indicated in the figure.
If not as specified, replace the valve guide.
Standard Inner diameter:
IN: 5.5095.539 mm {0.21690.2180 in}
EX: 5.5095.539 mm {0.21690.2180 in}
5. Calculate the valve stem to guide clearance by
subtracting the outer diameter of the valve stem
from the inner diameter of the corresponding
valve guide.
If not as specified, replace the valve and/or
the valve guide.
Standard clearance:
IN: 0.0240.069 mm {0.00090.0027 in}
EX: 0.0290.074 mm {0.00120.0029 in}
Maximum clearance:
0.10 mm {0.004 in}
6. Measure the protrusion height (dimension A) of
each valve guide without lower valve spring seat.
If not as specified, replace the valve guide.
Standard diameter:
IN: 12.212.8 mm {0.4810.503 in}
EX: 12.212.8 mm {0.4810.503 in}