Seitenansicht 341
CONTROL SYSTEM
U23
U
( ) : GCC specs.
*1
: Setting temperature fluctuates up or down in increments of 0.5, within the range of 15.0 to 29.0 (European
(L.H.D. U.K.) specs.) or 18.0 to 32.0 (GCC specs.). When the fan is OFF, the setting temperature can be
adjusted in the range of ±1.0.
*2
: If operated when in defroster correction, it returns to the condition prior to defroster operation.
*3
: Ambient temperature correction takes precedence. If operated when in defroster correction, it returns to the
condition prior to defroster operation. However, if it is off prior to defroster operation, it switches to automatic
control.
*4
: Ambient temperature correction takes precedence. When the fan is OFF, the A/C is fixed at off.
End Of Sie
AIRFLOW TEMPERATURE CONTROL
A6E854001044T04
Airflow temperature is controlled by the air mix actuator so that the passenger compartment temperature
remains at the target temperature (control computation value T1).
Control computation value T1 is the target temperature in the cabin set by the climate control unit based on
differences among set temperature, input temperature from the sensors, and sunlight intensity.
.
Temperatur
e setting
dial
*1
15.0 (18.0)
AUTO No change AUTO No change AUTO No change
15.528.5
(18.5
31.5)
29.0 (32.0)
Operation switch
Airflow mode control Air intake control A/C compressor control
Control before switched Control before switched Control before switched
Automatic
control
Manual
control
Automatic
control
Manual
control
Automatic
control
Manual
control
A6E8540T041
1 Set temperature
2 Sunlight intensity
3 Ambient temperature
4 Evaporator temperature
5 Cabin temperature
6 Airflow mode
7 Air intake mode
8 A/C compressor control condition
9 Signals
10 Climate control unit
11 Output
12 Feedback
13 Air mix actuator
14 Operation
15 Air mix doors
16 Airflow temperature changes
Seitenansicht 341